35
Ground Stud
Power Stud
VEHICLE
BATTERY
SNO-PRO V-PLOW w/SINGLE ACTING CYLINDERS & SPRING RETURN:
LEFT ANGLE FUNCTION - ELECTRICAL
Ground Connection
Internal in Plow Side Harness
Solenoid Control
Brown Wire
12vdc Switched
By Solenoid
D.)
C.)
E.)
B.)
Chassis Ground
Continuous Connection
A.)
12vdc Source
Black Wire
Must Be Ignition Switched
W2 Extend
V-Plow Touch Pad
BROWN
RED
GREEN
BLUE
WHITE
BLUE/BLACK
BLACK
WHITE/BLACK
W1 Retract
15a Fuse
What Happens:
A.) Ignition 'On' energizes the Controller Power source sending 12vdc into the Controller. Touch Pad Power Switch must be in the 'On' position.
B.) Pushing the 'Left Angle' button energizes the White 'W2 Extend' Wire, Blue/Black 'W1 Retract' Wire and the Brown 'Solenoid' Wire.
C.) The Brown 'Solenoid' Wire closes the Solenoid Contacts and sends 12vdc power to the Pump Motor.
D.) The White 'W2 Extend' Wire sends 12vdc power to the W2 Extend Valve Coil.
E.) The Blue/Black 'W1 Retract' Wire sends 12vdc power to the W1 Retract Valve Coil. See Next Page for Hydraulic Flow Chart.